Andreas
Stadlbauer1, Wilma van der Riet2, Erich Salomonowitz1
1MR Physics Group, Department of
Radiology, Landesklinikum St. Poelten, St. Poelten, Austria; 2European
MRI Consultancy (EMRIC), Strasbourg, France
To
study the CSF-flow dynamics in nine patients with enlarged ventricular system
and nine volunteers using time-resolved 3D MR velocity mapping.
Particle-path-lines were calculated to visualize CSF-flow patterns. From six
patients with suspected hydrocephalus internus, four showed a hypomotile and
two showed a hypermotile CSF-flow. From two patients with suspected normal
pressure hydrocephalus, one showed hypomotile and the other hypermotile
CSF-flow. One patient who had undergone a ventriculostomy 10 yrs ago showed
normal CSF-flow dynamics. These preliminary findings indicated changes in
CSF-flow dynamics in patients with enlarged ventricular system, but further
and more detailed studies are necessary.