Meeting Banner
Abstract #4057

Imaging of Oxygen Extraction Fraction Using Velocity Selective Excitation with Arterial Nulling (VSEAN)

Jia Guo1, Eric C. Wong2

1Department of Bioengineering, University of California San Diego, La Jolla, CA, United States; 2Department of Radiology and Psychiatry, University of California San Diego, La Jolla, CA, United States


We introduced a new method to image oxygen extraction fraction noninvasively using velocity selective excitation with arterial nulling (VSEAN). Compared to the QUIXOTIC method, VSEAN has following advantages: 1) higher SNR due to more relaxed venous blood; 2) no subtraction gives higher time efficiency; 3) insensitive to physiological noise; 4) a T2 map is generated every TR from multi-echo acquisition. Sequence design details were discussed and results from a human subject were presented.