Lingceng Ma1, Congbo Cai1, Shuhui Cai1, and Zhong Chen1
Conventional diffusion MRI tends to be of
limited use in real-time imaging, because motion can distort the images from
multiple scans. In this study, we propose a new imaging method, single-shot
diffusion mapping through overlapping-echo detachment planar (DM-OLED) method, together
with corresponding signal separation algorithm, to achieve reliable single-shot
diffusion mapping in the order of milliseconds. Numerical simulations were performed to verify the proposed method. The
results show that the method is accurate and efficient.