A BHT model was introduced to modify the penalty term of hybrid method for monitoring microwave ablation. Simulation results demonstrate that the proposed method is robust with the BHT model and can reconstruct more accurate temperature maps with different regularization parameters. Ex vivo experiment shows that the proposed method can achieve improved performance for rapid background shifting.