Classical and several rotating frame quantitative MR relaxation parameters have been used for evaluation of composition and structure of articular cartilage, and demonstrated to have variable sensitivity to orientation of the tissue in magnetic field. The orientation dependence of several relaxation parameters in articular cartilage have been previously investigated and were now further analyzed and compared to polarized light microscopy results. T1, adiabatic T1ρ with HS1 pulse and CW-T1ρ at 2 kHz spin-lock demonstrated the least orientation dependence. Usefulness of the parameters for osteoarthritis diagnostics, as reported in the literature, was evaluated together with the orientation sensitivity.