This study examined the relationship between R2* measurements from BOLD MRI and deoxyhemoglobin (HHb) measurements from near-infrared spectroscopy (NIRS) in calf muscle of subjects with varying degrees of peripheral artery disease (PAD). Following plantar-flexion exercise, the time required for R2* and HHb to recover to resting-state values was recorded. Linear regression was used to relate recovery time between R2* and HHb. This quantitative relationship enables estimation of HHb from MRI-measured R2*, which can help to improve the assessment of PAD since MRI can easily be performed for muscle tissue that is too deep for NIRS evaluation.