Abstract #3276
Thyroid T1 value increase in patients with hypothyroidism
Min Liu 1 , Fangfang Yu 2 , Guang Wang 3 , Tianjing Zhang 4 , and Jing An 4
1
the department of Radiology, Beijing
Chaoyang Hospital of Capital Medical University, Bei
Jing, Bei Jing, China,
2
the
department of Radiology, Beijing Chaoyang Hospital of
Capital Medical University, Bei Jing, China,
3
the
department of Endocrinology, Beijing Chaoyang Hospital
of Capital Medical University, Bei Jing, Bei Jing,
China,
4
MR
Collaborations NE Asia, Siemens Healthcare, Bei Jing,
Bei Jing, China
The aim of this study was to investigate thyroid T1
value in patients with hypothyroidism (HT). 21 untreated
females with clinical hypothyroidism (HT) and 21 healthy
control females underwent the thyroid T1 maps with
Modified Look-Locker Inversion Recovery technique at 3T
MR (Siemens TimTrio). All patients received
levothyroxine therapy and were followed after 6 months.
The results showed thyroid T1 value at 3T was
technically feasible and pretreatment thyroid T1 value
increase in HT patientscompared with normal woman.
After treatment, thyroid T1 value decreased. These
suggest T1 mapping may improve disease detection and
quantitatively monitor thyroid disease.