Meeting Banner
Abstract #4438

Reproducibility of Flow Measurements in Serial Studies of Patients with Untreated Aneurysms

Gabriel Acevedo-Bolton1, Andrew Lee1, Vitaliy L. Rayz1, Alastair Martin1, David A. Saloner2

1Radiology and Biomedical Imaging, UCSF, San Francisco, CA, United States; 2Radiology and Biomedical Imaging, VAMC/UCSF, San Francisco, CA, United States


MR velocimetry reproducibility was mesured in a cohort of 88 subjects with untreated aneurysms that were evaluated repeatedly over periods of time as long as 7 years. Reproducibility was also measured in exact replicas of the complex geometries of a subset of these subjects. Good agreement was found between experimental and computational flow measurements. In vivo studies were found to be reproducible with an error of measurement of 10%.