1Department of Radiology, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan; 2Imaging Research Center, Taipei Medical University, Taipei, Taiwan; 3Department of Electrical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan; 4Department of Electrical Engineering, National Taiwan University, Taipei, Taiwan


Previous studies have emphasized that the meniscis complex alignment of collagen fibers contributes to the execution of this function. The purpose of this study is to design a 2D multi-slice dual echo radial sequence with a minimal phase excitation pulse for facilitating visualization of the fiber orientation in human meniscus based on quantitative T2* mapping. Our findings demonstrate that the proposed method allows enhanced visualization of structural details of the human meniscus, and which contributes to derive the spatial T2* distribution and fiber orientation for diagnosing early degenerative changes.