A PARACEST MRI contrast agent, Yb-DO3A-oAA, can measure pH over a range of 6-7.9 pH units, with a precision of 0.206 pH units and an accuracy of 0.089 pH units. This measurement is based on a ratio of the two CEST effects of the PARACEST agent, which is independent of the agent's concentration or the samples T1sat relaxation time. Combined with a CEST-FISP acquisition protocol, the PARACEST agent was used to measure the extracellular pH (pHe) within a subcutaneous tumor and muscle of a MDA-MB-231 breast cancer model.