Julia V. Velikina1,
Kevin M. Johnson1, Steven R. Kecskemeti1, Patrick A.
Turski2, Alexey A. Samsonov1,2
1Medical
Physics,
We apply temporally constrained compressed sensing reconstruction of hybrid radial (in-plane)/Cartesian (through-plane) data acquisition to time-resolved contrast-enhanced MRA. We were able to obtain images with high spatial (0.86x0.86x2 mm) and temporal (1.2 s) resolution in patients with intracranial aneurysms.