Michael Bock1, Axel Joachim Krafft1,
Florian Maier1, Hans H. Paessler2
1Medical Physics in Radiology, German
Cancer Research Center (dkfz), Heidelberg, Germany; 2Center for
Knee & Foot Surgery/Sports Trauma, ATOS Clinic, Heidelberg, Germany
During
sports activities such as skiing temperature changes of up to 10 K have been
measured invasively. In this work we propose the use of MR temperature
measurements in the knee where the thermal stimulation is performed outside
the magnet. With a temperature-sensitive 3D FLASH sequence proton resonance
frequency data are acquired before and after stimulation, and image
co-registration is achieved with both a passive fixation device and an
alignment post-processing algorithm to calculate phase difference maps.