Meeting Banner
Abstract #2918

Evaluating Reliability of Performance Metrics for Bias Field Correction in MR Brain Images

Vitali Zagorodnov1, Zin Yan Chua1, Weili Zheng1

1Computer Engineering, Nanyang Technological University, Singapore, Singapore


Performance evaluation of nonuniformity correction approaches is usually performed indirectly, on the basis of remaining tissue intensity variability. However, inconsistencies between indirect measures reported in recent studies suggest that indirect measure might be poor proxies for true correction performance. This was confirmed by reliability study reported here. Reliability can be improved by evaluating the same metrics over conservative brain tissue masks and by applying slight smoothing to suppress image noise. On real brain MR data, due to potential difficulty in obtaining a conservative GM mask, we recommend using coefficient of variation (CV) measured on smoothed conservative WM mask.