Meeting Banner
Abstract #1934

Accuracy and Precision Analysis of a Semi-Automated Spatial Tag Position Detection Method

Erin Kristine Englund1, Bruce M. Damon2

1Biomedical Engineering, Vanderbilt University, Nashville, TN, USA; 2Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN, USA


Spatial tagging methods such as SPAMM provide information about tissue displacement during movement, however the analysis of tag position is time consuming and subjective. Using the proposed semi-automated method, it was possible to detect tag position in any image plane for spatial line tags. This decreased analysis time and subjectivity of tag detection. The method described is accurate to <0.03% for static images and can be applied to dynamic images as well.