Taehwa Hong1, Min-Oh Kim1, Dongyeob Han1, and Dong-Hyun Kim1
MR fingerprinting
(MRF) is a rapid method for quantifying multiple tissue properties. However, estimation
errors can increase when systematic imperfections including RF and gradient
coils exist. In this study, we analyzed estimation errors from non-ideal slice
profile and gradient delay by simulation. Our results showed that these
systematic imperfections can cause significant errors in parameter estimation.