Abstract #0719
Time efficient and robust perfusion measurement using Walsh-reordered time encoded pCASL
Federico von Samson-Himmelstjerna 1 , Jan Sobesky 2 , and Matthias Gnther 1
1
Fraunhofer MEVIS, Bremen, Bremen, Germany,
2
Center
for Stroke Research (CSB), Charit University Medicine
Berlin, Berlin, Germany
Time encoded (a.k.a Hadamard) pseudo continuous ASL
decodes N-1 time steps from N image acquisitions. All N
images are necessary for correct decoding. This means,
that corrupted images, e.g. by motion, can lead to
erroneous decoding and, thus, complete loss of data. To
overcome this limitation a Walsh-ordered and extended
Hadamard matrix is proposed for encoding. It allows the
reconstruction of perfusion data from the second image
acquisition on and a time resolution that increases with
the number of acquisitions. This renders the technique
robust against complete loss of data e.g. by motion of
agitated patients in the clinical setup.
This abstract and the presentation materials are available to members only;
a login is required.
Join Here